Monday, September 06, 2010
|
|

|
|
In industrial automation, Softing is a specialist for field bus technology and has established itself as a competent partner for networking automation systems and control solutions.
|
|
|
|
 |
 |
|
Fieldbus ASIC - UFC100-F1 Unified Fieldbus Controller
Fieldbus ASIC for FOUNDATION fieldbus and PROFIBUS PA. Fully pin and software compatible to Yamaha YTZ420 ("FIND1+") ASIC. The UFC100-F1 is suitable for field devices and controllers.
- Fully pin compatible to Yamaha YTZ420
- Fully software compatible to Yamaha YTZ420 and SPC4.2
- Low current consumption suitable for field devices
- Compliant to IEC 61158-2 Physical layer at 31.25 kbit/s
- Compliant to IEC 61158-4 Data Link layer
- RoHS compatible industry standard 44-pin PQFP package
- Operating voltage - 2.7 to 3.6 V
- Flexible 8-bit CPU bus interface suitable for all types of processors
- 128 byte FIFO can store one frame of most types
|
 |
|
Fieldbus Kit (FBK)
Interface to Foundation fieldbus or PROFIBUS PA for the fast and easy integration of existing field devices which currently have a HART- or serial interface.
-
Fully pin compatible to Yamaha YTZ420
-
Compact size makes it ideally suited for installation in most existing device housings
-
Pre-certified for use in zone 0
-
Connection to field device via: UART, I²C or SPI
-
2 AI, 2AO and 8 DI/DO additionally provided on the board
-
Ready-made templates allow quick customization to HART commands
|
|
| |
|
 |
|
|
|
 |
|
DP & PA Protocol Analyzer
|  |
|
 |
|
|
|
|
|
|
|
 |
 |
|
PROFIBUS PA Diagnostic Monitor
The Profibus PA Diagnostic Monitor, BC-230-PB, is used to examine the operation of a live Profibus-PA segment without interfering with its operation. It is powered by the fieldbus so that no battery or external power source is required. The monitor is useable also in hazardous areas. It is intended for maintenance personnel to verify segment operation or to troubleshoot an errant segment.
- Automatic segment test gives a OK/BAD indication without operator intervention
- Detects number of devices on the segment
- Displays device addresses decimal and hexadecimal
- Indicates device add & drop
- Displays number of detected retransmissions
- Displays signal level for all devices with indication of the lowest detected signal level
- Detects short circuits between either of signal wires and cable shield
- Measures average and peak noise in three bands: below, at and above fieldbus frequency
- Segment reports via USB to PC, displayed as Microsoft® Excel chart
- Protocol analysis for PROFIBUS DP and PA networks and devices
|
|
| |
|
 |
|
|
|
|
|
|
 |